ISO 13485 QMS Gap Diagnostic icon

ISO 13485 QMS Gap Diagnostic

Professional Updated 2026.08.29

Paste the following prompt into your AI chat to install this skill:

Please install @user_84a06754/iso13485 using the official guide at https://skillhub.cn/install/skillhub.md.

About this skill

Problem it addresses

Many medical device teams preparing for ISO 13485 certification do not simply lack documents; they do not know which gaps will become major nonconformities. Common issues include uncontrolled quality manuals, no appointed management representative, internal audits not closed out, CAPA records that state actions but never verify root causes, incomplete design history files, supplier evaluation without performance evidence, sterilization validation with OQ but no PQ, and unclear CE vigilance or clinical evaluation pathways. This skill turns scattered internal rules into a clause-by-clause gap view across chapters 4 to 8, so teams stop answering auditors with "we probably have it."

How the skill works

After taking product type, company scale, design involvement, sterilization, cleanroom use, target market, and target date, it checks the standard section by section:
- Chapter 4: QM, procedures, document control, record retention
- Chapter 5: management representative, management review, quality policy and objectives
- Chapter 7: 7.3 design controls, supplier ABC classification, batch records DHR, sterilization IQ/OQ/PQ
- Chapter 8: internal audit, CAPA, nonconforming product control, customer feedback, and data analysis

The output lists clause, current state, gap, severity, corrective action, and P0/P1/P2 priority, then proposes a certification timeline. For EU targets, it also checks CE technical documentation, vigilance reporting, advice reports, labeling language, and clinical evaluation routes.

Boundaries

It is useful for greenfield QMS buildout, gap remediation, and pre-audit mock checks. It does not replace notified-body audits, formal regulatory advice, or actual sterilization validation execution. The diagnosis is only as specific as the product, documents, operating records, and market scope you provide; a generic request such as "we want certification" will only yield a generic checklist, not an enterprise-specific risk assessment.

Use Cases

  • When starting ISO 13485, build a clause-by-clause gap list and identify missing documents and records.
  • When a quality manual and procedures exist, check gaps in design, supplier control, and sterilization.
  • Before a notified-body audit, mock auditor questions on internal audit, CAPA, and traceability.
  • For CE market entry, review technical files, vigilance reports, labels, and clinical evaluation.

Best For

  • Medical device quality manager: wants to identify missing QMS documents, records, and audit evidence.
  • Regulatory affairs specialist: wants to align ISO 13485 records with CE-market requirements.
  • Production or sterilization engineer: wants to verify batch records, traceability, and IQ/OQ/PQ files.
  • System engineer or owner: wants to turn audit, CAPA, and management review into an auditable chain.